logo
Products
PRODUCTS DETAILS
Home > Products >
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration

Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration

MOQ: One
Price: negotiable
Standard Packaging: Specialized packaging film
Delivery Period: lead time :35 work days
Payment Method: Western Union,MoneyGram,T/T
Supply Capacity: 1000 units per month
Detail Information
Place of Origin
Guangzhou, Guangdong, China
Brand Name
JETEX
Certification
ISO quality system certification,CRAA
Model Number
JTAHM Series
Features:
Purifying And Sterilizing Functions And Energy Saving
Air Volume:
1500 M³/h To 40,000 M³/h
Function:
Cooling, Heating, Humidifying, Dehumidifying, Filtering, Purifying And Sterilization
Panel Material:
Double Skin,insulation Foam,pre-painted Steel Sheet , Galvanized Steel Sheet, Stainless Steel Sheet(optional)
Name:
Hospital Air Handling Unit (AHU)
Feature:
Low Noise,high-efficiency Filtration,multi-functions , Precise Temperature And Humidity Control
Highlight:

hospital air handler with high-efficiency filtration

,

operating room AHU with filtration

,

high-efficiency air handling unit for hospitals

Product Description
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration
An air handler in HVAC, also known as an air handling unit (AHU), is a crucial component of any Heating, Ventilation, and Air Conditioning system.
A hospital air handling unit (AHU) is a critical part of the HVAC system that conditions and circulates air to maintain safety, health, and comfort for patients and staff. Hospitals require specialized AHUs with features like HEPA filters for infection control, precise temperature and humidity control for different zones (e.g., operating rooms versus patient rooms), appropriate pressure relationships (positive for clean areas, negative for isolation rooms), high air changeover rates, and built-in redundancy to prevent system failures.
The JTAHM series of medical clean air conditioning units is developed in accordance with the requirements of the "Technical Code for Hospital Clean Operating Department", the "Code for Construction and Acceptance of Cleanrooms" and the "Air Handling Units for Clean Operating Rooms".
The air volume handled by the unit ranges from 2,600 m³/h to 40,000 m³/h, allowing customized selection for different clean room requirements. The unit has two major series: the mixed air type (R series) and the fresh air type (F series).
Key Functions and Requirements
  • Infection Control: AHUs remove airborne contaminants using filters (like MERV-14 or higher, or HEPA) and control airflow patterns to prevent the spread of bacteria and viruses.
  • Air Quality: They filter out harmful particulates, ensuring high air quality for patients, visitors, and staff.
  • Temperature and Humidity Control: AHUs maintain precise temperatures and humidity levels, which are crucial for patient comfort, medical equipment functioning, and preventing the growth of pathogens.
  • Airflow and Pressure: Hospitals need different pressure levels for various zones; clean areas like operating rooms require positive pressure, while infectious isolation rooms need negative pressure to contain airborne contaminants.
  • Air Changeover Rates: Critical areas require specific, high air changeover rates to rapidly remove air contaminants.
Examples of Critical Hospital Areas and Their AHU Needs
  • Operating Rooms: Require high-efficiency filtration, positive pressure, and precise temperature and humidity control.
  • Infection Isolation Rooms: Need negative pressure to contain airborne diseases, along with appropriate filtration to remove pathogens before exhausting air.
  • Patient Rooms: Require comfortable temperature and humidity, along with good ventilation to support healing and staff safety.
Successful Cases
  1. Guangzhou Eighth People's Hospital
  2. The First Affiliated Hospital of Sun Yat-sen University
  3. Guangdong Provincial People's Hospital
  4. Shenzhen Longgang Central Hospital
  5. Beijing You'an Hospital
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration 0
Products
PRODUCTS DETAILS
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration
MOQ: One
Price: negotiable
Standard Packaging: Specialized packaging film
Delivery Period: lead time :35 work days
Payment Method: Western Union,MoneyGram,T/T
Supply Capacity: 1000 units per month
Detail Information
Place of Origin
Guangzhou, Guangdong, China
Brand Name
JETEX
Certification
ISO quality system certification,CRAA
Model Number
JTAHM Series
Features:
Purifying And Sterilizing Functions And Energy Saving
Air Volume:
1500 M³/h To 40,000 M³/h
Function:
Cooling, Heating, Humidifying, Dehumidifying, Filtering, Purifying And Sterilization
Panel Material:
Double Skin,insulation Foam,pre-painted Steel Sheet , Galvanized Steel Sheet, Stainless Steel Sheet(optional)
Name:
Hospital Air Handling Unit (AHU)
Feature:
Low Noise,high-efficiency Filtration,multi-functions , Precise Temperature And Humidity Control
Minimum Order Quantity:
One
Price:
negotiable
Packaging Details:
Specialized packaging film
Delivery Time:
lead time :35 work days
Payment Terms:
Western Union,MoneyGram,T/T
Supply Ability:
1000 units per month
Highlight

hospital air handler with high-efficiency filtration

,

operating room AHU with filtration

,

high-efficiency air handling unit for hospitals

Product Description
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration
An air handler in HVAC, also known as an air handling unit (AHU), is a crucial component of any Heating, Ventilation, and Air Conditioning system.
A hospital air handling unit (AHU) is a critical part of the HVAC system that conditions and circulates air to maintain safety, health, and comfort for patients and staff. Hospitals require specialized AHUs with features like HEPA filters for infection control, precise temperature and humidity control for different zones (e.g., operating rooms versus patient rooms), appropriate pressure relationships (positive for clean areas, negative for isolation rooms), high air changeover rates, and built-in redundancy to prevent system failures.
The JTAHM series of medical clean air conditioning units is developed in accordance with the requirements of the "Technical Code for Hospital Clean Operating Department", the "Code for Construction and Acceptance of Cleanrooms" and the "Air Handling Units for Clean Operating Rooms".
The air volume handled by the unit ranges from 2,600 m³/h to 40,000 m³/h, allowing customized selection for different clean room requirements. The unit has two major series: the mixed air type (R series) and the fresh air type (F series).
Key Functions and Requirements
  • Infection Control: AHUs remove airborne contaminants using filters (like MERV-14 or higher, or HEPA) and control airflow patterns to prevent the spread of bacteria and viruses.
  • Air Quality: They filter out harmful particulates, ensuring high air quality for patients, visitors, and staff.
  • Temperature and Humidity Control: AHUs maintain precise temperatures and humidity levels, which are crucial for patient comfort, medical equipment functioning, and preventing the growth of pathogens.
  • Airflow and Pressure: Hospitals need different pressure levels for various zones; clean areas like operating rooms require positive pressure, while infectious isolation rooms need negative pressure to contain airborne contaminants.
  • Air Changeover Rates: Critical areas require specific, high air changeover rates to rapidly remove air contaminants.
Examples of Critical Hospital Areas and Their AHU Needs
  • Operating Rooms: Require high-efficiency filtration, positive pressure, and precise temperature and humidity control.
  • Infection Isolation Rooms: Need negative pressure to contain airborne diseases, along with appropriate filtration to remove pathogens before exhausting air.
  • Patient Rooms: Require comfortable temperature and humidity, along with good ventilation to support healing and staff safety.
Successful Cases
  1. Guangzhou Eighth People's Hospital
  2. The First Affiliated Hospital of Sun Yat-sen University
  3. Guangdong Provincial People's Hospital
  4. Shenzhen Longgang Central Hospital
  5. Beijing You'an Hospital
Air Handler (AHU) For Hospital Operating Room With High-efficiency Filtration 0
Sitemap |  Privacy Policy | China Good Quality Air Handling Units Supplier. Copyright © 2024-2025 GUANGZHOU JETEX-LLOYD'S MACHINERY LTD . All Rights Reserved.